4 ton 410a piston size

20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …

4 ton 410a piston size. Refrigerant 410a 404a r22 refrigeration 134a r407c chart2 hvac 407c chillers conditioning r600 refrigerantsPiston size chart r22 goodman Piston r22 410a ton armstrong multiposition casedArmstrong em1p48bg 4 ton multiposition cased coil …

Thanks for the offer turtle, but according to the coil piston charts by Goodman, your range is way off. The only piston noted for any of the Goodman 2.5 ton outdoor units is the .065 piston. If you are thinking that the piston numbers noted in each of the catagories such as .058 to .065 or .078 to .065 are a range, you are reading the chart wrong.

The Goodman CAPF3636B6 evaporator coil is rated for a 3 ton output. In many system configurations, this coil may be larger in tonnage than its paired condenser. This is intentional, to maintain the overall efficiency of the entire system. Please note that in order for this coil to function, a furnace or blower and a condenser is required, all ...Compressor oil is needed in the air conditioning systems as lubricant and heat removal. Sealing of rotors and piston is another function of the oil. Expert Advice On Improving Your...20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that …Piston. A piston is a replaceable metering device with a fixed “bore.” It is essentially a piece of brass with a hole in the center; the smaller the bore, the less refrigerant flows through the piston, and vice versa. The advantage of a piston is that it is simple and can still be removed. You can also change the bore size and cleaned it if ... If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. PHYSICAL DATA (Copper Coil Models) UNIT SIZE SERIES 18BNG-E 24BNG-F 30BNG-D 36BNG-D 420NG-A 48BNG-E 600NG-C Compressor Type Scroll REFRIGERANT Puron (R-410A) Mar 26, 2016 · Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post. This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. 5742637-YIM-D-0620 4 Johnson Controls Ducted Systems Nomenclature. Z E 036 CA2 A 1 A A 1 A 1.

Piston r410a Solved 9.4 kg of r-134a fill a 0.7-m3 weighted Answer solved problem. ... 2 1/2 Ton R410A | Gemaire. Check Details. Piston Size Chart R22 Goodman - Best ...Residential R-410A Split System Air Conditioners. ICP has evaluated the use of ¼” and c” liquid lines for R-410A refrigerant air conditioner. cooling-only systems. R-410A refrigerant lends itself well to the use of smaller liquid lines in. either retrofit applications with existing linesets, or new systems when cost saving is a.Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...Piston size chart r410a Air conditioning piston size chart Refrigerant-410a in a piston/cylinder arrangement is initially at 60 f, x = 1. it is then Charging chart for 410a. ... Mini split pressure chartPiston goodman conditioning 410a matched 4 ton rheem 14 seer three phase condenser, ra1448Piston metering device hvac installing. ...If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. PHYSICAL DATA (Copper Coil Models) UNIT SIZE 18(A,G)KH 24(A,G)KH 30(A,G)KH 36(A,G)KH 42(A,G)KH 48(A,G)KH 60(A,G)KH Compressor Type Scroll REFRIGERANT R-410A

Refrigerant Piping. DESIGN AND FABRICATION GUIDELINES. Corp. 9351−L9 Revised July 30, 2018. APPLICATION AND DESIGN GUIDELINES. Introduction. The piping design of any air conditioning system will affect the performance, reliability, and applied cost of that system. 3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow. View and Download York R-410A technical manual online. SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS AND AIR HANDLERS. R-410A air handlers pdf manual …3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.

1865 silver dollar coin value.

Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separatelyMay 13, 2014 · I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model CHPF4860D6DB coil using R410A. The day after install, the system produced about a 14 degree F drop between the air intake and outlet vents. Flowcheck Pistons,Flowcheck Pistons. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. If it does not match, replace indoor piston with correct piston size in table below: NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed …*Heat Strip Size *Copper Refrigerant Line Set: Clear: 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler quantity. Add to cart. Compare SKU: J4AH4P30A1B00AA ... 4 Ton Goodman 15.2 SEER2 R410A Single Stage Heat Pump Split System. Rated 5.00 out of 5 $ 4,547.10 – $ 5,109.10-Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately

100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.Page 1. June 2004. PISTON KIT CHART (cont'd) 2. AMANA PISTON KIT CHART VALUE LINE BAG ASSY PISTONS. Mix-Matched evaporators and Amana condensers will require piston changes as listed below: WARNING. IT IS ESSENTIAL THAT. INDOOR AND OUTDOOR SECTIONS BE PROPERLY MATCHED.Apr 4, 2016 ... If the outdoor unit manufacturer does not recommend a piston size, ... Coils are suited for R-22 and R-410A ... Fixed Orifice Charging2, 3, 4 – Use ...Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999Apr 8, 2024 · 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler. Home / Featured Brands / Oxbox by Trane / 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler. $ 1,222.41 – $ 1,739.41. Buy in monthly payments with Affirm on orders over $50. Learn more. FEM4P4800AL - 4 Ton, R410A, Multi-position ECM Motor Fan Coil, With Piston, Aluminum Tubes, Aluminum Fin Use + and - keys to zoom in and out, arrow keys move the zoomed portion of the image Use + and - keys to zoom in and out, escape key to reset, arrow keys to change image in reset state or move the zoomed portion of the imageAccording to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either.a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b.4 - R-410A only. P. Cased - Painted. 6 - R-22 or R ... ¹ (ft²). ² Shipped with Coil. Note: For a properly matched system and piston sizing information, refer to ... The Goodman® GSZ13 heat pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life ...

Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative).

100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.Be the first to ask a question about this product! Product Features. Product DetailsEffective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV useResidential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with …Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual ... Page 21 Outdoor Unit Model Indoor Unit Model Piston Size(R410a) ...a. Exceptions for air conditioning (cooling only) applications, 1/4" liquid line may be used in: i. 1.5 ton applications for up to 100 equivalent feet (30.5 equivalent meters) with maximum 40’ (12.2 m) vertical lift ii. 2.0 ton applications for up to 75 equivalent feet (22.9 equivalent meters) with maximum 20’ (6.1 m) vertical lift b.The 3 to 15 ton Copeland Scroll Digital™ compressors described in this bulletin include the follow compressor model numbers: R-410A R-22 & R-407C ZPD34 to ZPD54K5 ZRD36 to ZRD81KC ZPD61-ZPD83, ZPD91, ZRD94 to ZRD125KC ZPD104, ZPD122KC ZPD103, ZPD120, ZPD137-182KC ZPD and ZRD digital scroll compressors are variable

Short travis kelce haircut.

Corey feldman net worth.

The range on flow rater piston of Goodman 2.5 ton condenser is from .059 to a .078 . Now if you needed a .059 and you put a .078 in it. It can flood back to get the compessor, also. Then vise versa it will starve the evaperator. You need to get the condenser model number and match it up to the evaperator coil model number or your …Piston 410a holooly410a goodman 4.0 ton rheem 14 seer r-410a central system ra1448aj1na, rh1p4821stanjaArmstrong em1p48bg 4 ton multiposition cased coil piston r22 or 410a. Check Details. Piston size chart 410a. Piston hvac r22 tapatalkPiston 410a holooly A cylinder/piston setup contains 1 l of saturated liquid refrigerant rHvac …2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ...According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either.Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use24ACC4: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5. Refrigerant Charge Adjustments. Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line*. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines ...Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.The range on flow rater piston of Goodman 2.5 ton condenser is from .059 to a .078 . Now if you needed a .059 and you put a .078 in it. It can flood back to get the compessor, also. Then vise versa it will starve the evaperator. You need to get the condenser model number and match it up to the evaperator coil model number or your going to buy a ...Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post.Reviews, rates, fees and rewards details for the Bon-Ton Credit Card. Compare to other cards and apply online in seconds. We're sorry, but the Bon-Ton Credit Card may no longer be ... The CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-51/61C-6F-1 coil is built to high standards and is backed by ... Piston 410a holooly410a goodman 4.0 ton rheem 14 seer r-410a central system ra1448aj1na, rh1p4821stanjaArmstrong em1p48bg 4 ton multiposition cased coil piston r22 or 410a. Check Details. Piston size chart 410a. Piston hvac r22 tapatalkPiston 410a holooly A cylinder/piston setup contains 1 l of saturated liquid refrigerant rHvac … ….

FIXED ORIFICE PISTON - R22 & R410A 3.0T - .068 OPENING - B1789868.Capacity (Tons) Piston Size* (R410a) Piston Kit 1.5 52 MAYORIACHP0052B 2 58 MAYORIACHP0058B 2.5** 063 / 065 MAYORIACHP0063B / 065A 3 70 MAYORIACHP0070B 3.5 75 MAYORIACHP0075B 4 83 MAYORIACHP0083B 5 90 MAYORIACHP0090B. 13 Table 5. Piston Superheat Charging ChartAvailable for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separatelyA 0.067 orifice is about right for a 3 ton 13SEER R-410A system, or at least really close, depending on which manufacturers chart you look at. Generally you should ignore the orifice size listed on the indoor coil, and go with what the outdoor unit calls for, which in this case is a TXV.Looking for the proper window size for your home can be a challenge. Our guide breaks down the standard sizes to help. Expert Advice On Improving Your Home Videos Latest View All G...INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5103 00 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. … Factory R410A TXV R-22 TXV = Mainline Kit # NAEA20401TX, NAEA20501TX, NAEA20601TX, and NAEA20701TX. Consult the chart below for proper size application. – comprehensive chart on pages 2 - 4 – Mainline kit FAST part Label Convert from R-410A PISTON to R-22 TXV Model Size 18 24 30 36 42 48 60 Hello, The cased "A" coil is a Model # TXCO49C4HPCO S/N Z0522LH5G made by American Standard. The 5 Ton condensor is made by Trane and it is Model # 2TTR1060A1000AA and S/N 5311T292F. I did remove the uncased coil from my air handler unit. It was in a housing that was mounted in front of the air handler. 4 To 5 Ton TXV Kit - R-410A Refrigerant. ( 5 Reviews) Model: Blueridge BGH4TXV03. $ 109.99. Or as low as. Buy in monthly payments with Affirm on orders over $50. Learn more. You save: 30%. Compare to: $157.92. 4 ton 410a piston size, Piston size chart r410a Air conditioning piston size chart Refrigerant-410a in a piston/cylinder arrangement is initially at 60 f, x = 1. it is then Charging chart for 410a. ... Mini split pressure chartPiston goodman conditioning 410a matched 4 ton rheem 14 seer three phase condenser, ra1448Piston metering device hvac installing. ..., According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi..., Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. ... This orifice (also referred to as a piston) is installed in an evaporator coil when the coil has a different tonnage rating than the condenser tonnage rating. Installation takes about 5 minutes, …, The CHX35 family of coils are designed with aluminum tube construction which provides great heat transfer and additional resistance to environmental contaminants. Durable components, such as corrosion-resistant casing and drain pans, help guard against unexpected service calls. CHX35-51/61C-6F-1 coil is built to high standards and is backed by ... , Maximum Fuse Size, 15. Blower Motor Type, PSC. Blower Motor HP, 1/3 HP. Blower Motor Speeds, 2. Filter Size, 19 7/8" x 21 1/2. Suction Line Size, 3/4". Liquid ..., Sx.e Vendor: ADVANCED DISTRIBUTOR PRODUCTS. Advanced Distributor Products #53, Florator Piston for 1.5 Ton R-22 and 2 Ton R-410A Air Handler Evaporator Coil. Specifications. Size: #53. Used On Item: 1.5 Ton R22, 2 Ton R410A Air Handler Evaporator Coil. Used On Model/Brand: 18, 24. QTY., 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ... , The electric vehicle revolution came to the streets of Munich this week in the form of a 40-ton, all-electric truck. The electric vehicle revolution came to the streets of Munich, ..., Piston Size R-22 R-410A Ton Piston Size Part # Piston Size Part # 1 41 100000035 41 100000035 1.5 53 100000036 49 100000049 2 59 100000037 53 100000036 2.5 67 100000039 59 100000037 3 73 100000041 67 100000039 3.5 80 100000044 73 100000041 4 84 100000045 76 100000042 5 93 100000047 93 100000047 ..., 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ..., Description Piston Size. Part Number. Qty; For Coils Size (MBTUH) 41 176799941. 10. 12; ... standard R-22 and R-410A pistons listed above (100 pistons total) in a ..., Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999, : Get the latest Shandong Binzhou Bohai Piston stock price and detailed information including news, historical charts and realtime prices. Indices Commodities Currencies Stocks, Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all …, The orifice will need to be changed. The question is whether the evaporator is rated for the 410 pressures. In the early days the R22 evaporators could not contain R410, but after 410 came out mfg’s started making heavier coils that could support 410 but R22 was cheaper and we had experience with it so we continued using it even though it …, Garage doors can make or break your home and equally important is the size. This contributes to functionality and overall style. Below we’ve rounded up a Expert Advice On Improving..., Unless you want to mismatch, why not just get a Rheem, Ruud or WeatherKing outdoor unit that is designed for that coil. WeatherKing is the economy model but still has a full metal jacket and scroll compressor in 4 ton. The 82 piston is for 4 ton, a 3.5 ton will come with a 73 piston to put in the RCBA-48 coil., goodman piston size. I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash., Some 14 SEER R410A evap. coils come with fixed and are an upsell to add the TXV for us. I'd use TXV on all the jobs if it was my choice, especially on a zoned system. luck dan. Are all the manufacturers using txv or do some manufactures use orifices. for 1.5 to 4 ton ac coils on 410a. I haven't installed any 410 yet., ADP Nominal 4 Ton ... 3/4" ODF on A-Coil 18-36 size models 2. 7/8" ODF ... R-22, R-410A, AC and Heat Pump compatible with appropriate TXV or piston installed., 4 TON AC/HP HORIZONTAL CASED "A" COIL, AIRFLOW:HORIZONTAL, CFM:1600, METERING DEVICE:PISTON, REFRIGERANT:R-410A(MUST CHANGE PISTON TO MAKE IT R-22), DESIGN PRESSURE:450 PSI, CONNECTION:3/8" X 7/8" SWEAT, DRAIN PAN:PLASTIC, DIMS:21"H X 21"W X 21 1/2"D, WEIGHT:43 LBS, IN BOX, MADE IN …, 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ..., Goodman-Amana B1789859 - Restrictor Orifice, B1789859- 13 SEER fixed orifice piston kit. Orifice opening of .059 for 2.0 ton R-22 and 2.5 ton R-410A units (GSX130301AB) Free shipping on orders over $99, Carrier tech support called and back and said, 56 or 57 - depending on what indoor coil it is. Product Data manual stated - #57 indoor piston and #46 outdoor piston (heating). If you want the manuals, let me know and I will email them to you. Instead of learning the tricks of the trade, learn the trade., Johnson Controls Ducted Systems Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 York International Corporation, 5005 York Drive, Norman, OK 73069, See the coil installation instructions for piston and TXV matches. 13 different models are available to suit a variety of situations and budgets ... 4 - 5 Ton Multi-Position Cased Evaporator Coil (21" W x 21" D x 30" H) Brand: ... Coil Size: 21"W x 30"H x 21"D. Ton: 5. 4. 4 to 5. Airflow: Upflow. Downflow. Horizontal. Refrigerant Type: R-410A ..., A piston does not come with this coil; it uses the piston from your condenser. If your condenser already uses R-410a refrigerant, all you will need to do is attach the piston from the condenser to the coil. If you have any further questions, please call us and we will be happy to assist you., 3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor , 14 seer split system air conditioner & heat pump 1.5-5 tons r410a (24 pages) Air Conditioner Trane Voyager Manual. Product (93 pages) ... * The ship-with literature bag will contain additional Outdoor Unit Piston Size* R-410A pistons for most applications. Piston Kit Capacity (Tons) (R410a) * Contact your local parts center to order the ..., Problem is I cant find any info on sizing of Rheem's pistons or the coil. Any help would be appreciated.” The Rheem air handler Model number told us that the 48 was for the BTU rating(4 ton as BaldLoonie pointed out) and the 82 stood for the piston size(as BaldLoonie pointed out as well)., Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual ... Page 21 Outdoor Unit Model Indoor Unit Model Piston Size(R410a) ..., Testing Instruments. Manifolds and Gauges. ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Advanced Distributor Products., 24ACC4: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5. Refrigerant Charge Adjustments. Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line*. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines ...