Troubleshooting guide: Why is your Honeywell thermostat flashing 'Cool on'? Get answers to fix HVAC issues fast...

Honeywell pro series flashing cool on. Resetting the Honeywell thermostat to the default factory setting will delete all your saved settings. Follow the steps below to reset the Honeywell Vision Pro 8000 series. Press the “MENU” button. Go to the “PREFERENCES” tab. Scroll down and click on “RESTORE TO FACTORY DEFAULT.”. Tap “YES” to confirm the factory reset.

To adjust program schedules (RTH221) Press SET until Set Schedule is displayed. Press s or t to set your Wake time (Mo-Su), then press SET. Press s or t to set the temperature for this time period, then press SET. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each time period.

The blinking “Cool On” message on a Honeywell thermostat display indicates that the system is restarting, batteries need replacing in the control panel, or a fault with the system. If the blinking persists for more than five minutes, contact a technician to perform diagnostics.Removing battery and putting it back in. Restarting it. Removing from wall and then putting it back. Changing my planned settings (what temperature at what time). Fiddling with all of the buttons on the face of the thermostat. Go to the furnace and tell me if there are any flashing lights at the furnace control board.The easiest way to create a portable QuickBooks database that you can access from different unconnected computers is to store the company file on a flash drive that you can physcia...There are several possible causes for a Honeywell thermostat blinking heat on message. Some of them are easy to fix, while others may require professional assistance. Here are some of the most common ones: Time Off Delay. Power Loss to the Condenser Unit or the Air Handler. Blown Fuses. Malfunctioning Control Board. Open High Limit Switch.Honeywell “cool on” blinking is basically an indicator that tells that the thermostat is under operational mode to cool the temperature. It takes around 5-7 minutes to completely operate. Just leave your thermostat for a couple of minutes and cool on flashing on thermostat would automatically go away.Honeywell News: This is the News-site for the company Honeywell on Markets Insider Indices Commodities Currencies Stocks

Final Thoughts. The reason why Honeywell thermostat blinking cool on is maybe the thermostat devices taking delay time to prevent the AC from short cycling. However, the cool on flashing may indicate that the AC is pumping cool air into your home. The blinking is supposed to go away within 5 minutes.Honeywell PRO 1000 Series User Manual View and Read online. Est. reading time 4 minutes. PRO 1000 Series Thermostat manuals and instructions online. ... When "Heat On" or "Cool On" is flashing, compressor protection is engaged. Select the system setting * Model TH1110E1000 has a larger display than shown in image.Not all thermostats have this feature, so check your manual to see if yours does. If not, your problem could be something else. Solution: If you have a battery tester, take out your batteries and test them. Replace if necessary. If not, replace them anyway and see if that stops your thermostat from blinking. 3.If you’re looking for a way to reduce your energy bills and increase the efficiency of your home, look no further than the Honeywell Pro Series thermostat. One of the key features ...Honeywell TH6210U2001/U T6 Pro Programmable Thermostat, 2 Heat / 1 Cool Heat Pump Or 1 Heat / 1 Cool Conventional: Amazon.com: ... Honeywell Home Large Cover Plate & Electrical Box Adaptor for T-Series Thermostats (THP2400A1080), White. $21.98 $ 21. 98. Get it as soon as Wednesday, May 1.This Honeywell Home PRO 3000 Non-Programmable Thermostat from Resideo offers basic operation such as a slide switch for selecting heat, cool, or operate the fan. The backlit digital display makes temperature and settings easier to read in various lighting conditions. SELECT A MODEL: PRO 3000 1 Heat/1 Cool Non-Programmable Digital Thermostat.

The screen shows cool on- solid not blinking. Fan on is displayed temperature is - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... I have a honeywell pro th4000 series system. the cool on indicator is flashing. I have followed the instructions in the operating manual, however ...Check that all vents in your home are open and unobstructed. Move any objects that may be blocking the vents, such as furniture or curtains. After cleaning or replacing the filters and ensuring vents are open, turn your thermostat back on and set it to “cool.”. Wait a few moments to see if the air begins blowing.Using a flash outdoors requires you to factor in more variables to get a good shot. You can’t light the whole landscape with a flash, and you can’t control any natural light source...Change the batteries. Replace air filters. Check the furnace door/power switch. Inspect air conditioner coils. Replace the thermostat. Call in an HVAC specialist. Honeywell thermostat set to cool but heating. Confirm the thermostat is set up properly. Lower the temperature on the thermostat.The easiest way to create a portable QuickBooks database that you can access from different unconnected computers is to store the company file on a flash drive that you can physcia...

Godzilla minus one showtimes near regal ua washington township.

Try Resetting the Thermostat to Factory Settings. 1. Honeywell Lyric Y Family. You must press the reset button and wait for 5-10 seconds, later release the button. 2. Honeywell 4000/6000/8000. Press and hold the “Reset” button for 5-10 seconds. Release the “Reset” button. 3.10.1 Honeywell Focus Pro 5000 Review Video; 11 Documents / Resources. 11.1 References; ... "Cool On" or "Heat On" is flashing. Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, ... Download Honeywell FocusPRO 5000 Series Manual. Advertisement.Leave the unit for a while and check whether the system is going to start cooling or not. Check other thermostat settings - something might have made your thermostat switch back to setup mode. Also, check the time on the device, as wrong settings can make the 'cool on' indicator start blinking. Replace the batteries or check the wiring ...If you see a cool on blinking on your thermostat it means that there is fault in the thermostat wiring or the battery is dying. The Cool On message also appears on screen when AC gives a 5 minutes cooldown time to the compressor or if blower motor is not working properly. A dirty Air Filter can also be the reason for cool on blinking on thermostat.The T6 Pro 7-Day Programmable Thermostat learns your heating and cooling cycle times to deliver the right temperature when you want it. With precise temperature control, the thermostat can automatically change from heating to cooling to help maintain the temperature you like most. Intuitive Design. The programmable thermostat comes with simple ...How to enable Auto mode on their Honeywell T6 Pro thermostat: How to turn on Auto Change in Honeywell ProSeries Thermostat. 1.Access the advanced settings menu (option 300). 2.Locate the setting that enables Auto mode. 3.Once enabled, use the Mode button on the thermostat to set it to Auto mode.

Thermostat features. The Honeywell T6 Pro Z-Wave Programmable Thermostat is a Z-Wave Plus certified thermostat designed to work with any Z-Wave compliant controller or gateway for easy programming and automation to deliver energy savings and comfort at the same time.Foreign companies don’t quite know what to make of China’s leadership transition. Maybe that’s why Honeywell CEO David M. Cote’s simple advice tonight—telling businesses not to ove...View and Download Honeywell PRO TH3000 Series owner's manual online. Pro TH3000 Series Non-Programmable Digital Thermostats. ... Page 6 Operating Manual Current inside temperature Temperature setting tf "Heat On" or "Cool Low battery warning (see page 9) On" is flashing, com- pressor protection engaged (see page 8). System Status • Cool On ...The T6 Pro Z-Wave Programmable Thermostat is a Z-Wave Plus certified thermostat capable of controlling up to three heat and two cool stages of heat pump, (incl. dual fuel heat pump systems) and up to two heat and two cool stages of conventional system (3H/2C HP, 2H/2C Conv.) It also measures, displays and reports % indoorHow Do I Unlock My Honeywell Thermostat Without the Code? For the T4 Pro model, the code will be 1234. To find the code on the T6 Pro Series, you would have to remove the faceplate and find the four-digit code on the top of the base (in the right corner). For the Honeywell 8000 series thermostats: Press SYSTEM and AUTO simultaneously.1. Check Thermostat Settings. 2. Check Your Thermostat's Battery. 3. Set Your Thermostat to The Lowest Temperature. 4. Check If Both the Outdoor and Indoor Units Have a Power Supply. 5. Clogged Air Filters Could Cause Honeywell Thermostat Blinking Cool On. 6. Dirty Coils Can Cause Honeywell Thermostat Flashing "Cool On" 7.With a standard footprint and simple interface, the T Series will enhance the entire thermostat experience for you and your customers alike. Features Wi-Fi touchscreen - Wi-Fi Connected version uses Lyric Platform application for smart devices Flexible scheduling or geofence technology Geofencing, 7-day, 5-2, 5-1-1 or non-programmable 6.89 sq ...Check that all vents in your home are open and unobstructed. Move any objects that may be blocking the vents, such as furniture or curtains. After cleaning or replacing the filters and ensuring vents are open, turn your thermostat back on and set it to “cool.”. Wait a few moments to see if the air begins blowing.PROA7PLUS ProSeries 7 inch All-in-One Panel. All-in-one Security system serves as a central hub for security and home automation with wireless controller, communicator, microphone, speaker and siren. Supports wide selection of sensors and devices using SiX™ two-way, wireless technology with highly secure AES-128 encryption.Watch this video on the Echo Pro Attachment Series of portable lawn tools with interchangeable attachments including a string trimmer, edger, and blower. Expert Advice On Improving...The FocusPRO™ 5000 series non-programmable digital thermostat provides electronic control of 24-volt (AC) conventional and heat pump systems or 750-millivolt (mV) heating systems and has up to 2 heat/2 cool stages for a heat pump or up to 2 heat/2 cool stages for a conventional system.

Aug 28, 2023 · 1. Wait For 10 Minutes. Before you decide to fix the Honeywell thermostat cool-on flashing error, you must wait for about 5 to 10 minutes. As there is a good chance that your thermostat is going through a restart or running some checks. Or it might be facing a slight delay or using the compressor protection feature.

Why is my Honeywell Thermostat Blinking Cool On? Five-Minute Compressor Delay. Low Thermostat Batteries. Power Outage. AC Unit Malfunction. Incorrect Thermostat Settings. Loose Wire Connections. Switching Modes. Faulty Thermostat Wiring. Blown Fuse. Low Refrigerant. How to Fix Honeywell Thermostat Cool On Blinking Light. 1.The FocusPRO™ 5000 series non-programmable digital thermostat provides electronic control of 24-volt (AC) conventional and heat pump systems or 750-millivolt (mV) heating systems and has up to 2 heat/2 cool stages for a heat pump or up to 2 heat/2 cool stages for a conventional system.Bot***** ***** light on right is flashing Customer attachment 6/9/2021 1:32:04 AM. ... I have an vision PRO TH8000 series Honeywell thermostat and Ineednto know how to turn on emergency heat only ... what is the red light at the top right corner of the vision pro 3 heat/ 2 Cool stat mean when it is used with a 2 stage heat pump with electric ...Flashing cool on. 3 years old, honeywell home pro series. Turned off circuit breakers for ac and furnace, turned back - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.https://raleighheatingandairservice.comHow to program a thermostat. Here we show the steps on how to program a Honeywell Focus Pro TH6000 series thermostat. ...Delay mode can take up to 5 minutes. But if you continually see the flashing messages after 5 minutes, there could be another issue with the voltage on your thermostat. In this case, calling an HVAC technician to come and verify voltage is in order. 2) Dying Batteries. Dying batteries could prevent your Honeywell thermostat from turning on heat.We have a PRO TH4000 series... model th4110D1007 date code 1410. The thermostat activates and changes during the middle of the night to the 'wake' setting giving us too much heat during the night time …

How much is a 1976 two dollar bill worth today.

Eliza st jude patient today.

Look along the top of the thermostat and locate the button which reads 'press'. Press down on the button. This will release the battery pack area, which will rotate outward, and then should slide completely up and out. Remove the old batteries and dispose of them properly. Replace with new batteries.Why is my Honeywell Thermostat Blinking Cool On? Five-Minute Compressor Delay. Low Thermostat Batteries. Power Outage. AC Unit Malfunction. …Replace the battery: Remove the old battery and replace it with a new one. Be sure to follow the manufacturer’s instructions for inserting the battery correctly. Reattach the thermostat cover: Once the new battery is inserted, snap the thermostat cover back into place. Turn the power back on: Finally, turn the power back on to the thermostat ...Feb 14, 2021 · Low Batteries. A blinking “Cool On” message can appear due to dying batteries, a power surge, or a power outage. Thermostat batteries last for an average of 10 months, so it is easy to tell when dead batteries are the culprit. Sometimes, a Honeywell thermostat can bounce back after a power outage without requiring a reset. The filter can improve the system’s performance or cause extensive damage when clogged with a significant amount of dirt. If the Cool On indicator flashes on your Honeywell thermostat, turn the air conditioner off and inspect the filter. A clogged air filter restricts the airflow into and out of the system, causing a malfunction.Hi, I have the Honeywell PRO 2000 thermostat. My apartment building turned the power on and off, and now my thermostat won't turn on the air conditioner. Remains at 79/80 degree.CLICK LINKS BELOW FOR ITEMS IN/RELATED TO VIDEO🍒 Here's my thermostat https://amzn.to/3cMWO9X🍒 Upgrade to this one? https://amzn.to/3Sc8L9v🍒 This one al...If the thermostat is blinking cool on but not working, this could indicate a power issue. Make sure to follow these steps to troubleshoot the problem and resolve it. Step 2: Check Thermostat Settings. When troubleshooting a Honeywell thermostat blinking cool on but not working issue, it is essential to check the thermostat settings.View and Download Honeywell TH8321WF1001 user manual online. TH8321WF1001 thermostat pdf manual download. Also for: Th8321wf1001u, Wi-fi visionpro 8000 series. ….

Flashing cool on. Contractor's Assistant: Do you know the model of your Honeywell thermostat? How old is it? 3 years old, honeywell home pro series. Contractor's Assistant: How long has this been going on with your Honeywell thermostat? What have you tried so far? Turned off circuit breakers for ac and furnace, turned back …The blinking “Cool On” message on a Honeywell thermostat display indicates that the system is restarting, batteries need replacing in the control panel, or a …PROA7 ProSeries 7 Inch All-In-One Panel. All-in-one Security system serves as a central hub for security and life safety with a wireless controller, communicator, microphone, speaker and siren. Supports wide selection of sensors and devices using SiX™ two-way, wireless technology with highly secure AES-128 encryption.Make sure the set temperature is higher than the actual room temperature. Check the heating system is powered on. Check the Receiver Box is powered and the Thermostat has a wireless signal (T3R only). Thermostat shows + - -. The temperature sensor of your Thermostat is faulty, contact your installer to repair or replace the Thermostat.1-48 of 129 results for "Honeywell Pro Series Thermostat" Results. Check each product page for other buying options. Honeywell. TH4110U2005/U T4 Pro Program Mable Thermostat, White. ... TH6220U2000/U T6 Pro Programmable Thermostat, 2 Heat / 1 Cool Heat Pump Or 2 Heat / 2 Cool Conventional, 2.27" x 6" x 5", White, Model:ITBD …A blinking “Cool On” message can indicate various causes, such as dying batteries, a power surge, or a power outage. Thermostat batteries generally last for an average of 10 months, making it easy to identify when dead batteries are responsible for the blinking message. However, sometimes a Honeywell thermostat can recuperate after a power ...2. How to unlock the Honeywell t6 series thermostat. If you have a t6 Pro Series Smart Thermostat, unlocking it is very straightforward. Simply press the center button on the front of the thermostat, under where it says "unlock." Next, enter the four-digit passcode. The default password on this model is "1234".If you're experiencing the Honeywell thermostat dispassionate on flashing issue, it are some troubleshooting steps that can help. Read this blog publish for more info. 914-666-9100Learn more about Honeywell Thermostats from Resideo at: https://bit.ly/3mD8GLwLearn how to reset in just a few steps. You can also find detailed instructions...If you need to reset your Honeywell Pro Series thermostat, the process is simple. First, locate the Reset button on the thermostat’s control panel. It should be located near the bottom of the device and may have a “Reset” label above or below it. Once you’ve located it, press and hold down for 10 seconds until all settings are restored ... Honeywell pro series flashing cool on, Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. Wait 5 minutes for the system to respond. Make sure heating and cooling temperatures are set to acceptable ranges: Heat: 40° to 90°F (4.5° to 32°C). Cool: 50° to 99°F (10° to 37°C). Compressor protection feature is engaged., Honeywell pro series about 1-2 years old. ... I have tried to push some buttons on the thermostat and nothing happens There is a flashing 2020 signal. there is a message "select" but when I push that button nothing happens. ... Blowing hot air on cool mode. HONEYWELL PRO SERIES. 1 HOUR I. Blowing hot air on cool mode JA: Do you know the model ..., Cool: Thermostat controls only the cooling system. Off: Heating and cooling systems are off. Auto: Thermostat automatically selects heating or cooling depending on the indoor temperature. Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat., or call Honeywell Customer Care toll-free at 1-800-468-1502. This manual covers the following models: TH5110D:For 1 Heat/1 Cool systems. TH5220D:For up to 2 Heat/2 Cool systems. TH5320U:For up to 3 Heat/2 Cool systems. MCR29404(Remove battery holder to find model number) FocusPRO. ®TH5000 Series 1 69-1923EFS—01. ENGLISH., Page 1: Thermostat Controls. Digital Thermostat FocusPRO ® 5000 Product Information Series Thermostat controls Display screen Low battery Auxiliary heat (Only Temperature warning for heat pumps with setting auxiliary heat) Current inside System temperature Heat Replace Status Inside Battery holder Setting Battery Cool On: Temperature buttons ..., Is you house HVAC thermostat blinking "cool on" or "heat on" and does not turn on the furnace or air conditioner? This is most often caused because power was..., If you replaced the batteries on your CT3200, CT3300, T8112, T8132 thermostat and are still getting the LOW BAT message, follow these steps: 1. Remove the batteries from the thermostat and place them in the opposite / wrong / incorrect position in the thermostat place the (+) on the (-) and vice versa). 2. Leave the batteries like that for …, All Honeywell thermostats that have batteries store the batteries in the control panel. Locate the batteries by removing the battery compartment tray or cover or by removing the unit’s faceplate. Carefully extract the batteries, and replace them. Be sure to place the batteries in the correct orientation. The battery-powered control unit of ..., Remove your thermostat from the wall, and open the battery holder on the side of your thermostat. Remove the old batteries and clean the inside of the holder. Insert the fresh set of batteries and close the battery holder. Remount the Honeywell thermostat on the wall again. Ensure that it clicks into position., The fix. If your thermostat is flashing cool on, wait for 5 minutes until the delay is over. Usually the thermostat delay should not take more than 5 minutes. However, if your thermostat is not blowing cold air after the delay period, there could be issues causing this problem. Let’s go to the next step to find out more., Feb 16, 2023 · Due to drained batteries, the heating or cooling feature of thermostats malfunctions. Go to your thermostat’s display and see the battery level. Insert the batteries of the required voltage so that your thermostat performs well. Replacing the batteries can debug the Honeywell thermostat won’t switch to cool. 4. , 7. Check Circuit Breaker/Fuse. If the Honeywell thermostat goes out in the aftermath of a power surge, fuse blowout, or circuit breaker tripping incident, it will not switch back on after changing its batteries unless you go through the process of replacing your house's blown fuse or resetting your home's relevant circuit breaker., Honeywell AC thermostats have a cool-on blinking light that indicates the unit is working to cool down the room. This could be due to either an incorrectly set temperature or because of an issue with the thermostat itself. If you find your Honeywell AC thermostat’s cool on light blinking, first check and make sure that you have selected a ..., Power outage or any interruptions in the power cause the thermostat to automatically switch to the setup mode. This is also one of the reasons why you find your Honeywell thermostat flashing cool on. Keep an eye on the clock and review all the settings accordingly. 3. Check Whether the Batteries Are Working., The Honeywell thermostat was blinking saving, wh ... (Honeywell 1000 PRO) for my. I have a very basic thermostat (Honeywell 1000 PRO) for my AC unit (which I asked for). It is set for 77. It will come on at 79 and shut off at 75. I would like to change that to less than 4 degrees. ... Customer: honeywell pro series JA: How long has this been ..., Up to 2 Heat/1 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems Electrical Connections Honeywell UWP Mounting System Operating Humidity Range (% RH) 5 to 90% RH, non-condensing Supply Voltage 20 to 30 Vac Switch Positions (System) HEAT-OFF-COOL-AUTO-EM.HEAT Switch Positions (Fan) AUTO-ON-CIRC-FOLLOW SCHEDULE Operating Temperature Range (F), Last updated. 8/29/22. Why is my thermostat display showing "wait," "waiting for equipment," or flashing "cool on"? Each thermostat model has a different display message when a delay occurs. This delay can be up to five minutes under normal operating conditions., Remove the old batteries, noting where the positive and negative ends are placed. Dispose of them properly and then insert your new batteries. Slide the battery compartment back into place, bottom first. A little push, and it should snap back into place. With fresh batteries, your thermostat should automatically turn back on in a few minutes., From https://www.justanswer.com/ythiJustAnswer Customer: I have a VisionPro th8000 series thermostat.JustAnswer Customer: A red light is flashing on the uppe..., Here are the steps you can take to troubleshoot your thermostat: Press and hold the "Menu" button on your Honeywell Pro Series thermostat. Use the ">" button to navigate through the menu options until you see "Reset", and then select it. Continue using the ">" button to navigate until you see "Factory Reset", and then select it., If your Honeywell Thermostat Vision Pro 8000 is having trouble, there are a few things you can do to troubleshoot the issue. First, check the batteries. If the batteries are low, they may need to be replaced. If the batteries are fine, then check the thermostat's settings. Make sure the thermostat is set to the correct mode (heating, cooling ..., , Position the Cover Plate on wall. Level and mark hole positions. See Figure 1. Drill holes at marked positions, and then lightly tap supplied wall anchors into the wall using a hammer. If your box contains red anchors, drill 7/32” (5.6 mm) holes. If your box contains yellow anchors, drill 3/16” (4.8 mm) holes., If you're experiencing the Honeywell thermostat dispassionate on flashing issue, it are some troubleshooting steps that can help. Read this blog publish for more info. 914-666-9100, 1-800-468-1502. 2. Introduction. The Honeywell T6 Pro Z-Wave Programmable Thermostat is a Z-Wave Plus certi- fied thermostat capable of controlling up to three heat and two cool stages of heat pump, (incl. dual fuel heat pump systems) and up to two heat and two cool stages of conventional system (3H/2C HP, 2H/2C Conv.), The Honeywell AC thermostat is displaying a blinking "Cool On" indicator. In this situation, it is important to troubleshoot the issue to identify the cause and find a solution. ... Read More Honeywell Pro Series Thermostat Fan Won't Turn Off: Troubleshooting Tips. Thermostat Solutions. Adt Thermostat Not Working: Troubleshooting and ..., or call Honeywell Customer Care toll-free at 1-800-468-1502. This manual covers the following models: TH5110D:For 1 Heat/1 Cool systems. TH5220D:For up to 2 Heat/2 Cool systems. TH5320U:For up to 3 Heat/2 Cool systems. MCR29404(Remove battery holder to find model number) FocusPRO. ®TH5000 Series 1 69-1923EFS—01. ENGLISH., When COOL ON blinks, it usually indicates a cooling system delay. But when it flashes for over 5 minutes, the primary reasons are power outage, sensor issues, wrong thermostat settings, low batteries, dirty filters and coils, wire problems, and wrong mode selections., When COOL ON blinks, it usually indicates a cooling system delay. But when it flashes for over 5 minutes, the primary reasons are power outage, sensor issues, wrong thermostat settings, low batteries, dirty filters and coils, wire problems, and wrong mode selections., All Honeywell thermostats that have batteries store the batteries in the control panel. Locate the batteries by removing the battery compartment tray or cover or by removing the unit's faceplate. Carefully extract the batteries, and replace them. Be sure to place the batteries in the correct orientation. The battery-powered control unit of ..., Works with Your Favorites. Connected to your existing WiFi, the T6 Pro Smart Thermostat is already part of the family. Integration with your Apple HomeKit and Amazon Echo lets you adjust your temperatures as easily as you change songs on your playlist. This thermostat also works with your heating systems stages, up to 3 Heat/2 Cool with heat pump., Dec 15, 2022 · 2) You have a conventional heating system. Another reason a honeywell thermostat will not display the cool option is that you don’t have a cooling system such as an air conditioner or a heat pump. Be sure that you have an air conditioner. You can try setting your thermostat to defrost and check if the condenser unit will engage. , Answer / Solution. The Non-Compliance Symbol () on a BW Clip4 may represent one of the following situations: A self-diagnostic test failure (an activated gas detector automatically performs a self-diagnostic test every 24 hours. If this test fails the gas detector beeps, flashes, and vibrates simultaneously for 15 seconds)